banner

Products

350kVA Mobile Silent Sc12e460d2 Sdec China Engine Diesel Generating Generator

350kVA Mobile Silent Sc12e460d2 Sdec China Engine Diesel Generating Generator

Mecca Power, as part of a Global Power Supplier initiative, provides a professional solution for the design, application
SHARE

Description

Basic Info
Model NO. MC
After-sales Service Responsible
Warranty 12 Months Warranty
Type Self-Starting Diesel Generator
Installation Method Fixed
Stroke Four Stroke
Cooling Method Water Cooling
Output Type AC Three Phase
Speed Low Speed
Conditions of Use Land Use
Usage Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit Automation Type
Excitation Mode Static Exciter
Engine Brand Chinese Engine Sdec
Alternator Brand Mecca, Leroy Somer, Stamford
Control Panel Deepsea/Comap/Datakom/Delixi/Smartgen and Others
Diesel Engine Generator Electrical Electric Start Generator Set
Canopy Type Silent Soundproof/Weather Proof/Anti-Rusted Proof
Frequency(Hz) 50Hz/60Hz
Voltage Output 230/400V
Application Mining/Hospital/Construction/Rental
Accessory[a] Spare Parts Documents
Accessory[B] Tool Kit
Governing Type Mech/Elec/ECU/Ecm/Adec/Hpcr
Certificate Available CE, ISO, OEM Authorization etc.
Diesel Generator Set Diesel Powered Generator
Genset Generator Silent Generator Price
Diesel Generator for Sale Three Phase Generator
Transport Package Both Standard Marine Packing and Compact Packing.
Specification As below Spec. with details
Trademark Mecca
Origin China
HS Code 85021100
Production Capacity 1000/Year
Product Description
Mecca Power, as part of a Global Power Supplier initiative, provides a professional solution for the design, application and after-sales support of generators.Strongly focused on innovation and the inherent flexibility of product design, Mecca Power has been successful in global markets with a broad and diverse range of genset power products that can operate autonomously or independently. parallel, on-site or remotely controlled.With more than 10 years of experience in manufacturing and exporting energy products, the Mecca team will advise you on product choices. Sdec Silent Diesel Power Electric Generator Power Generating Set Genset ISO9001 Approved

350kVA Mobile Silent Sc12e460d2 Sdec China Engine Diesel Generating Generator

350kVA Mobile Silent Sc12e460d2 Sdec China Engine Diesel Generating Generator

350kVA Mobile Silent Sc12e460d2 Sdec China Engine Diesel Generating Generator


View More Products Click Here......
General Feature
♦ Assembled by diesel engine and Brushless alternator.
Three filters as standard, fuel and water separator as optional.
♦ Radiator and fan with safety guard.
♦ Single bearing alternator IP 23, Insulation Class H.
♦ Heavy duty steel as base frame and 8hrs operation base fuel tank.
♦ Automatic control panel and 3 poles circuit breaker, internal cable.
♦ 12V or 24V battery, battery wires.
♦ Battery and float battery charger as standard supply scope.
♦ Fuel level indicator in meter and panel
♦ Optional soundproof canopy, ATS, synchronization panel, movable trailers.
Genset Main Technical Data
Genset ModelMC10YD-MC94YD
Prime Power7kW-68kW/9kVA-85kVA
Standby Power8kW-75kW/10kVA-94kVA
Frequency/Speed50Hz/1500rpm
Standard Voltage230/400V, Others as Application Requested
PhasesThree phases, four wires
Dimensions(L×W×H)mmOpen/Silent dimension as below list
100% Fuel Cons. (L/H)3.9~77.6
Base Fuel tank (hour)8~10
Alternator Specifications
Alternator ModelMECCA ALTERNATOR
Output power7kW-68kW
Voltage controlAVR
Number of phase3
Power factor (Cos Phi)0.8
Insulation ClassH
Number of Wires 6
Protection23
Altitude ≤ 1000 m
Number of Pole 4
Exciter typeAREP
Voltage regulation±0.5%
Totale Harmonic distortionat no load < 4 % - on load < 4 %
Bearing Single
CouplingDirect
Alternator Data
♦ Operate either 50Hz or 60Hz.♦Stator grease insulation covered
♦ Standard enclosure IP23, but IP44, IP55 for option♦Rotator and excitation high polymer
♦ Insulation class H. ♦ Resist the corruption oil and acid
♦ Shunt excitataion systems.♦Rotator balance is in accordance with BS5625
♦ AREP or PMG system for options. standard 12.5
♦ Automatic voltage regulator♦High-quality lubrication sealed long-time bearing
♦ Single bearing alternator♦Rotator silicon steel close tight
Standard Accessories
*Auto Control Panel*Starting Motor
*Main Ciruit Breaker*Exhaust silencer
*Fuel tank*Starting battery
*Base Frame*Float battery charger
*Filter *Flange

350kVA Mobile Silent Sc12e460d2 Sdec China Engine Diesel Generating Generator

350kVA Mobile Silent Sc12e460d2 Sdec China Engine Diesel Generating Generator



Item

Service

Option

Delivery Time
1EngineDoosan, Mtu, Mitsubishi, SME,Volvo, Deutz, Yanmar, Faw, YangDong, Aoling, Yuchai, Lovol, Wandi, ect.Marine and industry use Diesel, gas2-45days
2AlternatorStamford, Leroysomer, Meccalte, Marathon and customer requested alternatorsMedium and high voltage, Marine and industry use High IP GradeCT Drop kits, PMG, AVR2-15 days
3RadiatorFast, Beworld brandOriginal Radiator come with engineLocal made radiator with authorization by engine supplier2-7days
4CanopiesPowder coated and form mounted canopy,completely break down with hings,locks, raincap,bolts,screws, etc.Exhaust pipe and flanges Standard silent type canopy package Denyo type canopy package Rental type canopy package Telecom type canopy package Super silent type canopy package Containerized type canopy package Customerized type canopy package10days
5Base frameStandard base or simple iron baseAnti-Vibration mountingsWith/without tank, base tank volume no limitedFuel gauges and high pressure fuel pipes3days
6Control systemController: ComAp, DeepSea, Datacom, SmartGen etc.Breaker:Delixi,ABB, Chint, etc.Battery switch, battery charger, emergency stop botton, indicator, meters, CT and all wiring and harness.Batteries and cablesSpeed & lub oil & water temp sensors,A package of standard parts for assembly3days
7Exhaust SystemIndustrial and residential silencerFlexible connects and elbow3days
8
Others
Special demands

-----------------------------------------------------------------------------------------------Maintenance---------------------------------------------------------------------------------------------
General Troubleshooting This section lists the generating set for some common fault, the reasons for the failure and determines the method of fault. General operators can determine their own fault and note, maintenance it according to the brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation. Please remember the following suggestions before repairing: - Make sure that study the failure carefully before any operation. - Repair with the easiest way and most commonly used method. - Find the exact causes of failure and completely solve the fault. 1. Generator Sets Description of this section is for reference only. If the following failure occurs please contact the repairing agents. (Some models of control panel installed only parts of the following warning indicator light)
IconIndicator LightReasonFault Analysis
Low oil pressurealarmLow oil pressurealarmWhen oil pressure does notreduce normally, the light is on.-General because of a lack of oil or lubricationsystem failure caused by (refueling or replacingthe oil filter)-When occurs this fault should automaticallyshutdown generator sets immediately.
High watertemperaturealarmHigh watertemperaturealarmWhen the water temperaturehas risen to a level higher thanor equal to the sensor setting,the light is on.-General because of a lack of water or oilshortage, or overload.-When occurs this fault should automaticallyshutdown generator sets immediately.
Low fuel levelalarmLow fuel levelalarmWhen a fuel level has beendetected by the sensor fitted tothe daily tank, the light is on.-General because of a lack of water or oilshortage, or overload.-When occurs this fault should automaticallyshutdown generator sets immediately.
Battery chargerfault alarmBattery chargerfault alarmIf the charging system has fault,when engine running, the light isoff.-Battery charging system fault caused.-The light is on at the initial start, when thecharger reaches a certain speed, the light is off.-This failure will not lead to automatic shutdowngenerating units.
Crank failurealarmCrank failurealarmWhen the generator set failedthree times (or six times) in arow starting, the light is on.-Oil supply system or re-start the system failurecaused.
Overload orbreaker trippingalarmOverload orbreaker trippingalarmWhen overloading or Shortcircuit, the light is on. Trippingcircuit breakers cause generatorset load out.-In this fault, it need to load or unload some partsto eliminate short-circuit, and then re-close thecircuit breaker.

Introduction of Maintenance grade(Interval) for the generator set A Level Maintenance Interval (Daily Maintenance)1. Check Daily Report of Genset .2. Check fuel level and coolant level. 3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or other damage.4. Check the Air filter. The air filter should be replaced when necessary .5. Release fuel tank and fuel filter's water and sediment.6. Check the water cooling filter.7. Check starting battery and electrolyte, add electrolyte when necessary. 8. Check the starter, check noisy defect.9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.B Level Maintenance Interval (Less than 400 hours)1. Repeatedly check A Level Daily Maintenance steps.2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice and real fact. 3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF Grade of American Petroleum Institute.4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or it can be replaced. The replacement must be according to the environment and real fact.5. Replace the cooling system and add coolant concentration.6. Clean the crankshaft and inlet, outlet air- filter net. C Level Maintenance Interval (2000-3000 hours), Please do as follows:1. Repeatedly check A and B Level Daily Maintenance steps.2. Remove the tap of valve, clean and wash oil dirt and sludge.3. Fasten snails from each part (including running parts and fixed parts)4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.6. Check and adjust valve clearance.7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; clean and wash water tank radiator fins, then check the using capability of thermostat.Current Repair (D Level Maintenance)(3000-4000 hours)1. Check valve, valve seat and other wearing, repair or change it when necessary.2. Check P pump, quality of injection, repair and adjust it when necessary.3. Check and adjust connecting rod and fastening twisting torque.4. Check and adjust valve clearance.5. Check the trip of injector.6. Check and adjust tension of fan and generating belt.7. Clean and wash accumulation of carbon in inlet pipes.8. Clean and wash the core of air cooler.9. Clean and wash the whole oil lubrication system.10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.Medium Repair (6000-8000 hours)1. Including the items of minor repair.2. Disassemble generator(except crankshaft)3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.4. Check fuel supplying system, adjust oil pump and injector.5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.Overhaul (9000-15000hours)1. Including the items of intermediate repair.2. Disassemble all the parts in the generator.3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake and exhaust valve, a whole set of tools for generator repair 4. Adjust oil pump, injector and replace pump core, injector5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary

Our Contact